GPIB Command Dictionary
AFG2ENCoder subsystem
:AMPSTACS:SAT:FREQuency <real number>
These commands set/query the supervisory audio tone’s frequency. This signal is sent continuously whenever AFG2:AMPS:CHAN ‘Voice’ is used, but is interrupted when a FVC message is sent.
This command utilizes the “Real Number Setting Syntax” on page 299 but does not use the :STATe command.
Syntax
AFG2:AMPS:SAT:FREQ
Screen/field equivalent
AFG2:AMPS:SAT:FREQ controls the SAT Freq field on the
SIGNALING ENCODER screen when the Mode field is set to
:AMPSTACS:STANdard <string> :AMPSTACS:STANdard?
These commands set/query the radio standard for the encoder.
Syntax
AFG2:AMPS:STAN ‘AMPS’
‘TACS’
‘JTACS’
AFG2:AMPS:STAN?
Screen/field equivalent
AFG2:AMPS:STAN controls the Standard field on the SIGNALING
ENCODER screen when the Mode field is set to
Chapter 1 | 83 |