GPIB Command Dictionary
MEASure subsystem
:CANalyzer:ADC:EVMadc:LEVel <meas cmnd> :CANalyzer:ADC:EVMadc:LEVel?
These commands set/query the ADC for the EVM measurement. The ADC is a measure of how close the actual input signal is to the maximum input level.
This measurement utilizes the Number Measurement Syntax, but does not use the :METer command.
Syntax
MEAS:CAN:ADC:EVM:LEV <meas cmd>
!See “Number Measurement Syntax” on page 283. MEAS:CAN:ADC:EVM:LEV?
Example
MEAS:CAN:ADC:EVM:LEV? !displays the measurement
Screen/field equivalent
MEAS:CAN:ADC:EVM:LEV? reads the ADC FS measurement field on the CDMA ANALYZER screen when an EVM measurement is selected.
:CANalyzer:ADC:RHOadc:LEVel <meas cmnd> :CANalyzer:ADC:RHOadc:LEVel?
These commands set/query the ADC for the rho measurement. The ADC is a measure of how close the actual input signal is to the maximum input level.
This measurement utilizes the Number Measurement Syntax, but does not use the :METer command.
Syntax
MEAS:CAN:ADC:RHO:LEV <meas cmd>
!See “Number Measurement Syntax” on page 283. MEAS:CAN:ADC:RHO:LEV?
Example
MEAS:CAN:ADC:RHO:LEV? !displays the measurement
Screen/field equivalent
MEAS:CAN:ADC:RHO:LEV? reads the ADC FS measurement field on the CDMA ANALYZER screen when a rho measurement is selected. This measurement is also displayed on the CDMA GENERATOR screen.
218 | Chapter 1 |