Agilent Technologies E6380-90073 manual DECNAMPDTMFSYMBol?, IQPLotDISPlayI?, IQPLotDISPlayQ?

Models: E6380-90073

1 352
Download 352 pages 53.27 Kb
Page 271
Image 271

GPIB Command Dictionary

MEASure subsystem

:DEC:NAMP:DTMF:SYMBol?

This command queries the symbol number assigned by the encoder for each of the DTMF tones. As each tone is analyzed, the symbol that represents each tone is returned as a quoted string.

Syntax

MEAS:DEC:NAMP:DTMF:SYMB? !returns a quoted string

Screen/field equivalent

MEAS:DEC:NAMP:DTMF:SYMB? reads the Sym column on the SIGNALING DECODER screen when the Mode field is set NAMP-NTACand the Measure field is set to DTMF, and the Channel field is set to Voice.

:IQPLot[:DISPlay]:I?

This query returns an array of 384 values representing the I (horizontal) values for each decision point. The values are scaled to match the display (1 = average power of the RF Carrier).

Syntax

MEAS:IQPL[:DISP]:I?

Screen/field equivalent

MEAS:IQPL[:DISP]:I? does not correspond to any field in the IQPLOT screen but represents the horizontal values for the decision points on the plot.

:IQPLot[:DISPlay]:Q?

This command queries and returns an array of 384 values representing the Q (vertical) values for each decision point. The values are scaled to match the display (1 = average power of the RF Carrier).

Syntax

MEAS:IQPL[:DISP]:Q?

Screen/field equivalent

MEAS:IQPL[:DISP]:Q? does not correspond with a field in the IQPLOT screen but represents the vertical decision points shown on the plot.

Chapter 1

271

Page 271
Image 271
Agilent Technologies E6380-90073 manual DECNAMPDTMFSYMBol?, IQPLotDISPlayI?, IQPLotDISPlayQ?