CDANalyzer subsystem

:PNINcrement <real number> :PNINcrement?

These commands set/query the PN increment. If you know the PN incrment, enter it with this command to speed the PN offset search. If you do not know the increment, enter a 1.

This command utilizes the :INCR command of the “Real Number

Setting Syntax” on page 299.

Syntax

CDAN:PNIN <real number>!values from 1 to 256

CDAN:PNIN?

!returns the value of the PN increment

Screen/field equivalent

CDAN:PNIN controls the PN Incrment field on the CODE DOM screen when the CDMA standard is set to “IS-95 Only”. This field is displayed only when the Find PN field on the PN Setup menu is set to Auto.

:PNMode <string> :PNMode?

These commands set/query the PN offset mode.

‘Auto’ is used to calculate the system’s PN offset if it is unknown. When ‘Auto’ is selected, the CDAN:PNIN command can be used to enter a PN increment and speed the PN offset calculation.

‘Manual’ is used to enter a known PN offset. When ‘Manual’ is selected, the PN offset is entered using the CDAN:PNOF command.

Syntax

CDAN:PNM ‘Auto’

‘Manual’

CDAN:PNM? !returns the PN Offset mode

Screen/field equivalent

CDAN:PNM controls the Find PN field on the PN Setup menu of the CODE DOM screen, when the CDMA standard is set to “IS-95 Only”.