GPIB Command Dictionary

CONFigure subsystem

:SPOR10SPORT10SB10SP10:MODem:MODE <string> :SPOR10SPORT10SB10SP10:MODem:MODE?

These commands set/query the modem mode.

Syntax

CONF:SPOR10:MOD:MODE ‘Disable’

‘Ignore’

‘Answer’

‘Dial Back’

CONF:SPOR10:MOD:MODE? !returns quoted string

Screen/field equivalent

CONF:SPOR10:MOD:MODE controls the Modem Mode field of the MODEM CONFIGURE screen when the Serial Port field is set to Port 10.

:SPOR10SPORT10SB10SP10:MODem:CALL:ORIGinate

This command causes the modem to place a call using the dialing string entered with the CONF:SPOR10:MOD:CONN:NUMB command.

Syntax

CONF:SPOR10:MOD:CALL:ORIG

Screen/field equivalent

CONF:SPOR10:MOD:CALL:ORIG controls the Orignate subfield of the Call field on the MODEM CONFIGURE screen when the Serial Port field is set to Port 10.

:SPOR10SPORT10SB10SP10:MODem:CALL:DISConnect

This command causes the modem to disconnect from the call in progress. It also cancels any pending call origination retries (CONF:SPOR10:MOD:CONN:RETRy). This field is inactive when CONF:SPOR10:MOD:MODE ‘Disable’ command is used.

Syntax

CONF:SPOR10:MOD:CALL:DISC

Screen/field equivalent

CONF:SPOR10:MOD:CALL:DISC controls the Disconnect subfield of the Call field on the MODEM CONFIGURE screen when the Serial Port field is set to Port 10.