GPIB Command Dictionary

CDANalyzer subsystem

:GAIN:MODE <string> :GAIN:MODE?

These commands set/query the mode of the Gain field, allowing you to choose between an autoranging gain (‘Auto’) or a fixed gain (‘Hold’).

This command may conflict with the CDMA analyzer’s settings CAN:PATH:GAIN and CAN:PATH:MODE. For example, if autoranging is turned off (‘Hold’) in the CDMA analyzer and turned on in the Code Domain Analyzer (‘Auto’), the ‘Hold’ setting will always override the ‘Auto’ setting. When autoranging is turned off, setting either analyzer’s path gain will automatically change the other’s to the same setting.

For average power measurements, use the CAN:POW:GAIN:MODE command.

Syntax

CDAN:GAIN:MODE ‘Auto’

‘Hold’

CDAN:GAIN:MODE?

Screen/field equivalent

CDAN:GAIN:MODE sets the Auto/Hold subfield of the Gain field of the CODE DOM screen, when the CDMA standard is set to “IS-95 Only”.

:GAIN:VALue?

This command queries the gain of the code domain analyzer. This command will only be enabled when autoranging is turned on (CDAN:GAIN:MODE ‘Auto’).

Syntax

CDAN:GAIN:VAL? !returns 0 dB,6 dB,12 dB,18 dB,24 dB, 30 db, 36 dB

Screen/field equivalent

When the CDMA standard is set to “IS-95 Only”, the

CDAN:GAIN:VAL? reads the lower subfield of the Gain field of the

CODE DOM screen when the upper subfield is set to Auto,

Chapter 1

123

Page 123
Image 123
Agilent Technologies E6380-90073 manual Gainmode string GAINMODE?, GAINVALue?