GPIB Command Dictionary

RFANalyzer subsystem

RFANalyzer subsystem

:ATTenuator <string> :ATTenuator?

These commands set/query the amount of input attenuation in the path of the selected input port. CONF:ATT:MODE ‘Auto’ overrides this command.

Syntax

RFAN:ATT ‘0 dB’ ‘5 dB’ ‘10 dB’ ‘15 dB’ ‘20 dB’ ‘25 dB’ ‘30 dB’ ‘35 dB’

RFAN:ATT?

Screen/field equivalent

RFAN:ATT controls to the lower subfield of the Input Atten field on the RF ANALYZER screen.

:ATTenuator:MODE <string> :ATTenuator:MODE?

These commands set/query the RF autoranging mode.

CONF:ATT:MODE ‘Hold’ overrides this command.

Syntax

RFAN:ATT:MODE ‘Auto’

‘Hold’

RFAN:ATT:MODE?

Screen/field equivalent

RFAN:ATT:MODE corresponds to the Auto/Hold subfield of the Input Atten field on the RF ANALYZER screen