GPIB Command Dictionary

MEASure subsystem

:CDANalyzer:IS2000:TRACe:ABSolute:POWer[:BASic][:VALue]?

IS-2000 only. This query returns an array of 128 values representing the true (absolute) power of the Walsh channel on which the Marker is currently positioned.

NOTE

The value returned represents the absolute power of the Walsh channel

 

not the supplemental channel. The power of the supplemental channel

 

must be read directly from the Marker Lvl value on the CODE

 

DOMAIN screen, or with the MEAS:CDAN:IS2000:TRAC:ABS:POW[:BAS]:ALL?

 

query.

 

Syntax

 

MEAS:CDAN:IS2000:TRAC:ABS:POW[:BAS][:VAL]?

 

Screen/field equivalent

 

MEAS:CDAN:IS2000:TRAC:ABS:POW[:BAS][:VAL]? returns values

 

that match the values displayed for Power, Fast Power, and Power &

 

Noise measurements when CD pwr unit is set to Abs from the

 

Reference image on the CODE DOMAIN screen when the CDMA

 

standard is set to “IS-2000”.

:CDANalyzer:IS2000:TRACe:ABSolute:POWer[:BASic]:ACTive?

IS-2000 only. This query returns the active channel information for the Code Domain trace when making a Power, Fast Power, or Fast Power Synchronize measurement. The returned entity consists of an integer representing the number of active channels followed by a four-value record for each channel. The four values for each record are:

Channel number

Spread factor for this channel

Power for this channel

A fourth (ignore it) value

Syntax

MEAS:CDAN:IS2000:TRAC:ABS:POW[:BAS]:ACT?

Screen/field equivalent

MEAS:CDAN:IS2000:TRAC:ABS:POW[:BAS]:ACT? has no equivalent field on the CODE DOMAIN screen. The information can only be returned when the CDMA standard is set to “IS-2000”, the measurement selected is Power, Fast Power or FstPwr Sync, and CD pwr unit is set to Abs on the Reference image of the CODE DOMAIN screen.

242

Chapter 1

Page 242
Image 242
Agilent Technologies E6380-90073 manual CDANalyzerIS2000TRACeABSolutePOWerBASicVALue?