GPIB Command Dictionary
AFG2ENCoder subsystem
:NAMPsNTACs:FVC:RATE <real number> :NAMPsNTACs:FVC:RATE?
These commands set/query the data rate of the encoded message.
This command utilizes the “Real Number Setting Syntax” on page 299 but does not use the :STATe command.
Syntax
AFG2:NAMP:FVC:RATE <real number>
AFG2:NAMP:FVC:RATE?
Screen/field equivalent
AFG2:NAMP:FVC:RATE controls the Data Rate field on the
SIGNALING ENCODER screen when the Mode field is set to
:NAMPsNTACs:FVC:AM <real number> :NAMPsNTACs:FVC:AM?
This command sets/queries the data level when the AFG2:DEST ‘AM’ command is used. The data level units are %.
This command utilizes the “Real Number Setting Syntax” on page 299.
Syntax
AFG2:NAMP:FVC:AM
AFG2:NAMP:FVC:AM?
Screen/field equivalent
AFG2:NAMP:FVC:AM controls the Data Level field when AFGen2 To field is set to AM on the SIGNALING ENCODER screen when the Mode field is set to