GPIB Command Dictionary
AFG2ENCoder subsystem
:AMPSTACS:SAT:FM <real number> :AMPSTACS:SAT:FM?
These commands set/query the SAT level when the AFG2:DEST ‘FM’ and AFG2:AMPS:CHAN ‘Voice’ commands are used. The SAT level’s units are kHz.
This command utilizes the “Real Number Setting Syntax” on page 299.
Syntax
AFG2:AMPS:SAT:FM
AFG2:AMPS:SAT:FM?
Screen/field equivalent
AFG2:AMPS:SAT:FM controls the SAT Level field when AFGen2 To field is set to FM on the SIGNALING ENCODER screen when the Mode field is set to
:AMPSTACS:SAT:LEVel <real number> :AMPSTACS:SAT:LEVel?
These commands set/query the SAT level when the AFG2:DEST ‘Audio Out’ and AFG2:AMPS:CHAN ‘Voice’ commands are used. The SAT level units are mV.
This command utilizes the “Real Number Setting Syntax” on page 299.
Syntax
AFG2:AMPS:SAT:LEV
AFG2:AMPS:SAT:LEV?
Screen/field equivalent
AFG2:AMPS:SAT:LEV controls the SAT Level field when AFGen2 To field is set to Audio Out on the SIGNALING ENCODER screen when the Mode field is set to
82 | Chapter 1 |