3Com Swich 7750 Series
Command Reference Guide – Information Center Chapter 1 Information Center Commands
1-24
% Current terminal logging is off
1.1.21 terminal monitor Syntax
terminal monitor
undo terminal monitor
View
User view
Parameter
none
Description
Use the terminal monitor command to enable the debugging/log/trap information
terminal display function.
Use the undo terminal monitor command to disable these functions.
By default, these functions are enabled for console users and terminal users.
This command only takes effect on the current terminal where the commands are input.
The debugging/log/trap information can be output to the current terminal, beginning in
user view. When the terminal monitor is shut down, no debugging/log/trap information
will be displayed in local terminal, which is equals to having performed undo terminal
debugging, undo terminal logging, undo terminal trapping commands. When the
terminal monitor is enabled, you can use terminal debugging / undo terminal
debugging, terminal logging / undo terminal logging and terminal trapping /
undo terminal trapping respectively to enable or disable the corresponding
functions.
Example
# Disable the terminal monitor.
<3Com> undo terminal monitor
% Current terminal monitor is off
1.1.22 terminal trapping Syntax
terminal trapping
undo terminal trapping