Command Reference Guide – Multicast Chapter 5 PIM Configuration Commands
5-7
PIM DR(designated router) is 10.10.1.20
Table 5-2 Description on the fields of the display pim interface command
Field Description
PIM version Version of PIM
PIM mode PIM mode enabled on the VLAN
interface (DM or SM)
PIM query interval Hello packet interval
PIM neighbor limit Limit of the PIM neighbors on the VLAN
interface. No neighbor can be added any
more when the limit is reached
PIM neighbor policy Filtering policy of the PIM neighbors on
the current interface
PIM DR Designated router
Syntax
display pim neighbor [ interface interface-type interface-number ]
View
Any view
Parameter
interface-type interface-number: Interface type and interface number, used to specify
the VLAN interface.
Description
Use the display pim neighbor command to view the PIM neighbor information
discovered by the VLAN interface of the switch. If the VLAN interface parameter is
specified, only the PIM neighbor information about the specified VLAN interface is
displayed.
Example
# Display the PIM neighbor information discovered by the VLAN interface of the
neighbor.
<3Com> display pim neighbor
Neighbor’s Address Interface Name Uptime Expires
8.8.8.6 VLAN-interface10 1637 89