3Com Switch 7750 Series
Command Reference Guide – Login Chapter 1 Login Commands
1-11
Use the undo history-command max-size command to revert to the default history
command buffer size.
Example
# Set the size of the history command buffer of AUX 0 to 20 to enable it to store up to
20 commands.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] user-interface aux 0
[3Com-ui-aux0] history-command max-size 20
1.1.10 idle-timeout Syntax
idle-timeout minutes [ seconds ]
undo idle-timeout
View
User interface view
Parameter
minutes: Number of minutes. This argument ranges from 0 to 35,791.
seconds: Number of seconds. This argument ranges from 0 to 59.
Description
Use the idle-timeout command to set the timeout time. The connection to a user
interface is terminated if no operation is performed in the user interface within the
timeout time.
Use the undo idle-timeout command to revert to the default timeout time.
You can use the idle-timeout 0 command to disable the timeout function.
The default timeout time is 10 minutes.
Example
# Set the timeout time of AUX 0 to 1 minute.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] user-interface aux 0
[3Com-ui-aux0] idle-timeout 1 0