3Com Switch 7750 Series
Command Reference Guide — Basic Port Commands Chapter 1 Port Basic Configuration Commands
1-7
Input(normal): - packets, - bytes
- broadcasts, - multicasts, - pauses
Input: - input errors, 0 runts, - giants, 0 throttles, 0 CRC
0 frame, - overruns, - aborts, - ignored, - parity errors
Output(total): 1288 packets, 116919 bytes
0 broadcasts, 886 multicasts, 0 pauses
Output(normal): - packets, - bytes
- broadcasts, - multicasts, - pauses
Output: 0 output errors, - underruns, - buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
- lost carrier, - no carrier
Table 1-2 Description on the fields of the display interface command
Field Description
Ethernet1/0/1 current state Enable/disable status of the current
Ethernet port
IP Sending Frames' Format Ethernet frame format
Hardware address Port hardware address
The Maximum Transmit Unit The maximum transmit unit (MTU)
Media type Media type
Port hardware type Port hardware type
Flow-control is enabled Flow-control status of the port
The Maximum Frame Length Maximum frame length allowed on the
port
Allow jumbo frame to pass Whether Jumbo frame is allowed on the
port.
Port monitor last value: 5 Delay of reporting down state to the
system for a port
PVID Default VLAN ID of the port
Mdi type Network cable type
Port link-type Port link type
Tagged VLAN ID Identify the VLANs whose packets will
be forwarded with tags on the port.
Untagged VLAN ID Identify the VLANs whose packets will
be forwarded without tags on the port.
Last 300 seconds input: 0 packets/sec 0
bytes/sec
Last 300 seconds output: 0 packets/sec
0 bytes/sec
Rate and number of incoming and
outgoing packets in the last 300 seconds