3Com Switch 7750 Series
Command Reference Guide – Login Chapter 1 Login Commands
1-3
Example
# Configure the telnet 10.110.100.1 command to be executed automatically after
users log into VTY 0.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] user-interface vty 0
[3Com-ui-vty0] auto-execute command telnet 10.110.100.1
% This action will lead to configuration failure through ui-vty0. Are you
sure?[Y/N]y
1.1.3 databits Syntax
databits { 7 | 8 }
undo databits
View
User interface view
Parameter
7: Sets the data bits to 7.
8: Sets the data bits to 8.
Description
Use the databits command to set the databits for the user interface.
Use the undo databits command to revert to the default data bits.
Execute these two commands in AUX user interface view only.
The default data bits is 8.
Example
# Set the data bits to 7.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] user-interface aux 0
[3Com-ui-aux0] databits 7
1.1.4 display user-interface Syntax
display user-interface [ type number | number ] [ summary ]