3Com Switch 7750 Series
Command Reference Guide – AAA, RADIUS, HWTACACS, EAD Chapter 1 AAA & RADIUS & HWTACACS
Configuration Commands
1-26
z After the accounting optional command is used for a RADIUS scheme, the
system will no longer send real-time accounting update packets and
stop-accounting packets for any user who adopts the RADIUS scheme.
z This configuration takes effect only on the accounting using this RADIUS scheme.
Example
# Execute the accounting-optional command for the RADIUS scheme CAMS.
<3Com>system-view
System View: return to User View with Ctrl+Z.
[3Com] radius scheme CAMS
[3Com-radius-cams] accounting optional
1.2.3 data-flow-format
Syntax
data-flow-format data { byte | giga-byte | kilo-byte | mega-byte } packet
{ giga-packet | kilo-packet | mega-packet | one-packet }
undo data-flow-format
View
RADIUS scheme view
Parameter
data: Sets the unit of measure for data.
byte: Specifies to measure data in bytes.
giga-byte: Specifies to measure data in gigabytes.
kilo-byte: Specifies to measure data in kilobytes.
mega-byte: Specifies to measure data in megabytes.
packet: Sets the unit of measure for packets.
giga-packet: Specifies to measure packets in giga-packets.
kilo-packet: Specifies to measure packets in kilo-packets.
mega-packet: Specifies to measure packets in mega-packets.
one-packet: Specifies to measure packets in packets.
Description
Use the data-flow-format command to set the units of measure for data flows sent to
RADIUS servers.
Use the undo data-flow-format command to restore the default units of measure.
By default, the unit of measure for data is byte and that for packets is one-packet.