3Com Switch 7750 Series
Command Reference Guide – SNMP & RMON Chapter 2 RMON Configuration Commands
2-1
Chapter 2 RMON Configuration Commands 2.1 RMON Configuration Commands
2.1.1 display rmon alarm
Syntax
display rmon alarm [entry-number ]
View
Any view
Parameter
entry-number: Alarm entry index, in the range of 1 to 65535. If you do not specify this
argument, the configuration of all alarm entries is displayed.
Description
Use the display rmon alarm command to display the configuration of a specified alarm
entry or all the alarm entries.
Related command: rmon alarm.
Example
# Display the configuration of all the alarm entries.
<3Com> display rmon alarm
Alarm table 1 owned by abc is VALID.
Samples type : delta
Variable formula : 1.3.6.1.2.1.2.2.1.11.67111554<ifInUcastPkts.67111554>
Sampling interval : 10(sec)
Rising threshold : 100(linked with event 7)
Falling threshold : 10(linked with event 8)
When startup enables : risingOrFallingAlarm
Latest value : 0
Table 2-1 Description on the fields of the display rmon alarm command
Field Description
Alarm table Alarm entry
abc Entry creator
VALID Valid for alarm entries corresponding to the index