3Com Switch 7750 Series
Command Reference Guide – AAA, RADIUS, HWTACACS, EAD Chapter 1 AAA & RADIUS & HWTACACS
Configuration Commands
1-69
System View: return to User View with Ctrl+Z.
[3Com] hwtacacs scheme test1
[3Com-hwtacacs-test1] stop-accounting-buffer enable
1.3.18 timer quiet Syntax
timer quiet minutes
undo timer quiet
View
HWTACACS scheme view
Parameter
minutes: Length of the timer in minutes, in the range of 1 to 255. By default, the primary
server must wait five minutes before it resumes the active state.
Description
Use the timer quiet command to set the duration that a primary server must wait
before it can resume the active state.
Use the undo timer quiet command to restore the default (five minutes).
With the timer quiet command configured, the switch stops processing the request
packets from users when the communication between the switch and the server is
interrupted. The switch does not send user request packets to the server until the wait
time of the switch is equal to or greater than the time configured with the timer quiet
command.
Related command: display hwtacac.
Example
# Set the quiet timer for the primary server to ten minutes.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] hwtacacs scheme test1
[3Com-hwtacacs-test1] timer quiet 10
1.3.19 timer realtime-accounting Syntax
timer realtime-accounting minutes
undo timer realtime-accounting