3Com Switch 7750 Series
Command Reference Guide – PoE Chapter 2 PoE PSU Supervision Configuration Commands
2-3
Table 2-2 Description on the fields of the display poe-power alarm command
Field Description
PSU is in normal state: The PSU operates normally.
NOTLINK: The PSU is not linked (the controller fails to
communicate with this PSU or the PSU is not inserted). You
can clear the failure by powering off the PSU or inserting a
PSU.
INERROR: PSU input error. Restoring the normal AC input can
clear the error.
OUTERROR: PSU output error (No normal DC output from the
PSU).
HIGHVOL: Overvoltage on the PSU (the PSU is shut down
because its outputs overvoltage).
HIGHTEP: It is overheated in the PSU.
FANERROR: The fan fails.
CLOSE: The PSU is shut down.
CURLIMIT: The current of the PSU is limited.
The alarm
information about
PoE PSU1
Absent: The PSU is absent.
Syntax
display poe-power dc-output state
View
Any view
Parameter
None
Description
Use the display poe-power dc-output state command to display the DC output state
of the PoE PSUs in-use.
Example
# Display the DC output states of the in-use PoE PSUs.
<3Com> display poe-power dc-output state
DC Output State : Normal