Commands Listed in Alphabetical Order
Examples BUS:B1:FLEXRAY:SOURCE CH4 sets the FLEXRAY source to channel 4.
BUS:B1:FLEXRAY:SOURCE? might return BUS:B1:FLEXRAY:SOURCE CH1
indicating the FLEXRAYsource is channel 1.
BUS:B<x>:I2C:ADDRess:RWINClude
Sets and returns whether the read/write bit is included in the address.
Group Bus
Syntax BUS:B<x>:I2C:ADDRess:RWINClude {<NR1>|OFF|ON}
BUS:B<x>:I2C:ADDRess:RWINClude?
Arguments <NR1> = 0 does not include the read/write bit in the addess; any other value
includes the read/write bit in the address..
OFF does not include the read/write bit in the address.
ON includes the read/write bit in the address.
Examples BUS:B1:I2C:ADDRESS:RWINCLUDE ON includes the read/write bit in the
address.
BUS:B1:I2C:ADDRESS:RWINCLUDE? might return
BUS:B1:I2C:ADDRESS:RWINCLUDE 0 indicating the read/write bit is not
included in the address.
BUS:B<x>:I2C{:CLOCK|:SCLK}:SOUrce
Sets or returns the I2C SCLK source for bus <x>, where x is the bus number.
Conditions This command requires a DPO4EMBD or DPO4COMP application module.
Group Bus
Syntax BUS:B<x>:I2C{:CLOCK|:SCLK}:SOUrce {CH1|CH2|CH3|CH4|
D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:I2C{:CLOCK|:SCLK}:SOUrce?
2-96 MSO4000 and DPO4000 Series Programmer Manual