Commands Listed in Alphabetical Order
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition
Sets or returns the trigger condition for FLEXRAY.
Group Search
Syntax SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition
{SOF|FRAMETypeid|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition?
Arguments SOF sets the FLEXRAYtrigger condition to start of frame.
FRAMETypeid sets the FLEXRAY trigger condition to a frame type id.
CYCLEcount sets the FLEXRAYtrigger conditionto cycle count.
HEADer sets the FLEXRAY trigger condition to header.
DATA sets the FLEXRAY trigger condition to data.
IDANDDATA sets the FLEXRAY trigger condition to ID and data.
EOF sets the FLEXRAYtrigger condition to EOF.
ERROR sets the FLEXRAY trigger condition to an error.
Examples SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:CONDITION ERROR sets
the FLEXRAY condition to ERROR
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:CONDITION? might
return SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:CONDITION SOF
indicating the FLEXRAY condition iss tart of frame.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue
Sets or returns the binary data string to be used for FLEXRAY cyclecount high
value.
Group Search
Syntax SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:
HIVALue <QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:
HIVALue?
MSO4000 and DPO4000 Series Programmer Manual 2-339