Commands Listed in Alphabetical Order
Conditions This command requires a DPO4EMBD application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:I2C:DATa:SIZe <NR1>
TRIGger:A:BUS:B<x>:I2C:DATa:SIZe?
Arguments <NR1> is the length of the data string in bytes.
TRIGger:A:BUS:B<x>:I2C:DATa:VALue
Sets or returns the binary data string used for I2C triggering if the trigger condition
is DATA or ADDRANDDATA.Applies to bus <x>, where x is the bus number.
Conditions This command requires a DPO4EMBD application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:I2C:DATa:VALue <QString>
TRIGger:A:BUS:B<x>:I2C:DATa:VALue?
Arguments <QString> is the binary data string, where the number of bits is 8 times the
number of bytes specied. The only allowed characters in the s tring are 0, 1,
and X.
TRIGger:A:BUS:B<x>:LIN:CONDition
Sets or returns the trigger condition for LIN.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:LIN:CONDition
{SYNCField|IDentifier|DATA|IDANDDATA|WAKEup|SLEEP|ERROR}
TRIGger:A:BUS:B<x>:LIN:CONDition?
Arguments SYNCField sets the LIN trigger condition to sync eld.
IDentifier sets the LIN trigger condition to identier.
2-416 MSO4000 and DPO4000 Series Programmer Manual