Commands Listed in Alphabetical Order
DATA sets the LIN trigger condition to data.
IDANDDATA sets the LIN trigger condition to id and data.
WAKEup sets the LIN trigger condition to wake up.
SLEEP sets the LIN trigger condition to sleep.
ERROR sets the LIN trigger condition to error.
Examples TRIGGER:A:BUS:B1:LIN:CONDITION ERROR sets the LIN trigger condition
to error.
TRIGGER:A:BUS:B1:LIN:CONDITION? might return
TRIGGER:A:BUS:B1:LIN:CONDITION SYNCFIELD indicating the LIN trigger
condition is sync eld.
TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue
Sets or returns the binary data string to be used for LIN trigger if trigger condition
is ID or IDANDDATA.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue <QString>
TRIGger:A:BUS:B<x>:LIN:DATa:HIVALue?
Arguments <QString> is a quoted string that is the binary data string used for LIN trigger if
the trigger condition is ID or IDANDDATA.
Examples TRIGGER:A:BUS:B1:LIN:DATA:HIVALUE "11001010" sets the high value
to 11001010.
TRIGGER:A:BUS:B1:LIN:DATA:HIVALUE? might return
TRIGGER:A:BUS:B1:LIN:DATA:HIVALUE "XXXXXXXX"indicating
the high value is don’t care.
TRIGger:A:BUS:B<x>:LIN:DATa:QUALier
Sets or returns the LIN data qualier. This only applies if the trigger condition is
IDANDDATAor DATA.
Group Trigger
MSO4000 and DPO4000 Series Programmer Manual 2-417