Commands Listed in Alphabetical Order
TRIGger:A:PULse? (Query Only)
Returns the A pulse trigger parameters.
Group Trigger
Syntax TRIGger:A:PULse?
Related Commands TRIGger:A:EDGE?,TRIGger:A:LOGIc?
Examples TRIGGER:A:PULSE? might return :TRIGGER:A:PULSE:CLASS TRANSITION
TRIGger:A:PULse:CLAss
Sets or returns the type of pulse on which to trigger.
Group Trigger
Syntax TRIGger:A:PULse:CLAss {RUNt|WIDth|TRANsition}
TRIGger:A:PULse:CLAss?
Related Commands TRIGger:A:RUNT?,TRIGger:A:PULSEWIDth?,TRIGger:A{:TRANsition|:
RISEFall}?,TRIGger:A:TYPe
Arguments RUNt triggers when a pulse crosses the rst preset voltage threshold but does not
cross the second preset threshold before recrossing the rst.
WIDth triggers when a pulse is found that has the specied polarity and is either
inside or outside the specied time limits.
TRANsition triggers when a pulse crosses both thresholds in the same direction
as the specied polarity and the transition time between the two threshold
crossings is greater or less than the specied time delta.
Examples TRIGGER:A:PULSE:CLASS WIDTH species a width pulse for the A trigger.
TRIGGER:A:PULSE:CLASS? might return :TRIGGER:A:PULSE:CLASS WIDTH
indicating that a pulse was found that is of the specied polarity and width.
2-440 MSO4000 and DPO4000 Series Programmer Manual