Commands Listed in Alphabetical Order
POWer:DISplaySets or returns the display state for the power application. This is the equivalent
to pressing the Tes t buttonand then selecting the power application. The same
control is provided for each application.
Conditions This command requires a DPO4PWR application module.
Group Power
Syntax POWer:DISplay {OFF|ON|0|1}
POWer:DISplay?
Arguments OFF or 0 turns off the display settings.
ON or 1 turns on the display settings.
Examples POWER:DISPLAY 1 turns on the display.
POWER:DISPLAY? might return :POWER:DISPLAY 0 indicating that the display
is off.
POWer:GATESOurceSets or returns the gate source for the power application.
Conditions This command requires a DPO4PWR application module.
Group Power
Syntax POWer:GATESOurce {CH1|CH2|CH3|CH4|REF1|REF2|REF3|REF4|NONe}
POWer:GATESOurce?
Arguments CH1–CH4 sets an analog channel as the gate source.
REF1–REF4 sets a reference as the gate source.
NONe is set when the gate source is not used in the application.