Commands Listed in Alphabetical Order
Returns PASS,FAIL,orNA.
Examples POWER:HARMONICS:RESULTS:IEC:HARM3ALTERNATE? might return
POWER:HARMONICS:RESULTS:IEC:HARM3ALTERNATE PASS indicating the
test result.
POWer:HARMonics:RESults:IEC:HARM5ALTernate? (Query Only)
Returns the overall harmonics test result for the 5th harmonic.
NOTE. The command returns NA the harmonic limit does not apply.
Conditions This command requires a DPO4PWR application module.
Group Power
Syntax POWer:HARMonics:RESults:IEC:HARM5ALTernate?
Returns PASS,FAIL,orNA.
Examples POWER:HARMONICS:RESULTS:IEC:HARM5ALTERNATE? might return
POWER:HARMONICS:RESULTS:IEC:HARM5ALTERNATE PASS indicating the
test result.
POWer:HARMonics:RESults:IEC:POHC? (Query Only)
Returns the IEC POHC measurement.
Conditions This command requires a DPO4PWR application module.
Group Power
Syntax POWer:HARMonics:RESults:IEC:POHC?
Examples POWER:HARMONICS:RESULTS:IEC:POHC? might return
:POWER:HARMONICS:RESULTS:IEC:POHC 0.5 indicating that the
IECPOHCissetto0.5A.
2-264 MSO4000 and DPO4000 Series Programmer Manual