Commands Listed in Alphabetical Order
TRIGger:A:BUS:B<x>:SPI:CONDition
Sets or returns the trigger condition for a SPI trigger. Applies to bus <x>, where x
is the bus number.
Conditions This command requires a DPO4EMBD application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:SPI:CONDition
{SS|STARTofframe|MISO|MOSI|MISOMOSI}
TRIGger:A:BUS:B<x>:SPI:CONDition?
Related Commands BUS:B<x>:SPI:IDLETime,BUS:B<x>:SPI:FRAMING
Arguments SS species the Slave Selection condition.
STARTofframe is applicable when BUS:B<x>:SPI:FRAMING is set to
IDLEtime. When the trigger condition is set to STARTofframe,theinstrument
triggers on the rst SPI clock after an idle time when there are no clocks.
MISO species the Master-In Slave-Out condition.
MOSI species the Master-Out Slave-In condition.
MISOMOSI species the Master-In Slave-Out and Master-Out Slave-In conditions.
TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO}:VALue
Sets or returns the binary data string to be used for a SPI trigger if the trigger
condition is MISO or MISOMOSI. Applies to bus <x>, where x is the bus number.
Conditions This command requires a DPO4EMBD application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO}:VALue <QString>
TRIGger:A:BUS:B<x>:SPI:DATa{:IN|:MISO}:VALue?
Arguments <QString> is the binary data string, where the number of bits is 8 times the
number of bytes specied. The only allowed characters in the st ring are 0, 1,
and X.
MSO4000 and DPO4000 Series Programmer Manual 2-423