Command Groups
Table 2-25: Measurement Commands (cont.)
Command Description
MEASUrement:IMMed:SOUrce Sets or returns the “from” source for all single
channel immediate measurements
MEASUrement:IMMed:SOUrce2 Sets or returns the source to measure “to” for
phase or delay immediate measurements
MEASUrement:IMMed:TYPe Sets or returns the type of the immediate
measurement
MEASUrement:IMMed:UNIts? Returns the units of the immediate
measurement
MEASUrement:IMMed:VALue? Returns the value of the immediate
measurement
MEASUrement:INDICators? Returns all measurement indicator
parameters
MEASUrement:INDICators:HORZ<x>? Returns the position of the specied
horizontal measurement indicator
MEASUrement:INDICators:NUMHORZ? Returns the number of horizontal
measurement indicators currently being
displayed
MEASUrement:INDICators:NUMVERT? Returns the number of vertical measurement
indicators currently being displayed
MEASUrement:INDICators:STATE Sets or returns the state of visible
measurement indicators
MEASUrement:INDICators:VERT<x>? Returns the value of the specied vertical
measurement indicator
MEASUrement:MEAS<x>? Returns all measurement parameters
MEASUrement:MEAS<x>:COUNt? Returns the number of values accumulated
since the last statistical reset
MEASUrement:MEAS<x>:DELay? Returns the delay measurement parameters
for the specied measurement
MEASUrement:MEAS<x>:DELay:DIRection Sets or returns the search direction to use for
delay measurements
MEASUrement:MEAS<x>:DELay:EDGE<x> Sets or returns the slope of the edge to
use for delay “from” and “to” waveform
measurements
MEASUrement:MEAS<x>:MAXimum? Returns the maximum value found since the
last statistical reset
MEASUrement:MEAS<x>:MEAN? Returns the mean value accumulated since
the last statistical reset
MEASUrement:MEAS<x>:MINImum? Returns the minimum value found since the
last statistical reset
MEASUrement:MEAS<x>:SOURCE[1] Sets or returns the channel from which
measurements are taken
2-28 MSO4000 and DPO4000 Series Programmer Manual