Commands Listed in Alphabetical Order
Arguments <NR1> is the number of samples used for the mean and standard deviation
statistical accumulations
Examples POWER:STATISTICS:WEIGHTING 4 sets statistical weighting to four samples.
POWER:STATISTICS:WEIGHTING ? might return
:POWER:STATISTICS:WEIGHTING 4 indicating that statistics weighting is
currently set to 4 samples.
POWer:SWLoss:CONDCALCmethodSets or returns the power application switching loss conduction calculation
method.
Conditions This command requires a DPO4PWR application module.
Group Power
Syntax POWer:SWLoss:CONDCALCmethod {VOLTage|RDSon|VCEsat}
POWer:SWLoss:CONDCALCmethod?
Arguments VOLTage sets voltage as the conduction calculation method.
RDSon sets RDSon as the conduction calculation method.
VCEsat sets VCEsat as the conduction calculation method.
Examples POWER:SWLOSS:CONDCALCMETHOD RDSon sets the conduction calculation
method to RDSon.
POWER:SWLOSS:CONDCALCMETHOD ? might return
:POWER:SWLOSS:CONDCALCMETHOD VOLT indicating that the conduction
calculation method is set to Voltage.
POWer:SWLoss:CONDuction:ENERGY:MAX? (Query Only)Returns the maximum conduction energy for switching loss calculation.
Conditions This command requires a DPO4PWR application module.
Group Power
2-298 MSO4000 and DPO4000 Series Programmer Manual