Commands Listed in Alphabetical Order
SYNCFrame sets the FLEXRAYerror type for a triggerto SYNCFrame.
STARTupnosync sets the FLEXRAYerror type fora trigger to STARTupnosync.
NULLFRStatic sets the FLEXRAY error type for a trigger to NULLFRStatic.
NULLFRDynamic sets the FLEXRAYerror type for a trigger to NULLFRDynamic.
Examples TRIGGER:A:BUS:B1:FLEXRAY:ERRTYPE SYNCFRAME sets the FLEXRAY
trigger type is SYNCFRAME.
TRIGGER:A:BUS:B1:FLEXRAY:ERRTYPE? might return
TRIGGER:A:BUS:B1:FLEXRAY:ERRTYPE CRCHEADER indicating the
FLEXRAY trigger type is CRCHeader.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALueSets or returns the binary data string to be used for FLEXRAY frame ID high
value.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue <QString>
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:HIVALue?
Arguments <QString> is a quoted string that is the binary frame id high value.
Examples TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:HIVALUE “11001100101” sets the
frame id high value to 11001100101.
TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:HIVALUE? might return
TRIGGER:A:BUS:B1:FLEXRAY:FRAMEID:HIVALUE "XXXXXXXXXXX"
indicating the frame id high value is don’t care.
TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifierSets or returns the FLEXRAY frame ID qualifier.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:FLEXray:FRAMEID:QUALifier
{LESSThan|MOREThan|EQUal|UNEQual|LESSEQual|MOREEQual|
INrange|OUTrange}
2-408 MSO4000 and DPO4000 Series Programmer Manual