Commands Listed in Alphabetical Order
Examples TRIGGER:A:BUS:B1:FLEXRAY:DATA:VALUE “11001101” sets the FLEXRAY
data value for triggering to 11001101.
TRIGGER:A:BUS:B1:FLEXRAY:DATA:VALUE? might return
TRIGGER:A:BUS:B1:FLEXRAY:DATA:VALUE "XXXXXXXX" indicating the
FLEXRAY data value is don’tcare.
TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE
Sets or returns the end of le type used for FLEXRAY trigger.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE {STATic|DYNAMic|ANY}
TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
Arguments STATic species triggering on the STATICend of le type.
DYNAMic species triggering on the DYNAMIC end of le type.
ANY species triggering on a STATIC or DYNAMIC end of le type.
Examples TRIGGER:A:BUS:B1:FLEXRAY:EOFTYPE ANY sets the FLEXRAY end of le
type to ANY.
TRIGGER:A:BUS:B1:FLEXRAY:EOFTYPE? might return
TRIGGER:A:BUS:B1:FLEXRAY:EOFTYPE STATIC indicating the
FLEXRAY end of le type is STATIC
TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE
Sets or returns the error type be used for FLEXRAYtrigger.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE
{CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|
NULLFRDynamic}
TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
Arguments CRCHeader sets the FLEXRAY error type for a trigger to CRCHeader.
CRCTrailer sets the FLEXRAY error type fora trigger to CRCTrailer.
MSO4000 and DPO4000 Series Programmer Manual 2-407