Commands Listed in Alphabetical Order
Syntax TRIGger:A:SETHold:CLOCk:THReshold {<NR3>|TTL}
TRIGger:A:SETHold:CLOCk:THReshold?
Arguments TTL species a preset TTL high level of 1.4 V.
<NR3> is the clock level, in volts.
Examples TRIGGER:A:SETHOLD:CLOCK:THRESHOLD TTL species the preset TTL value
of 1.4 V as the clock threshold for the setup and hold trigger.
TRIGGER:A:SETHOLD:CLOCK:THRESHOLD? might return
:TRIGGER:A:LOGIC:SETHOLD:CLOCK:THRESHOLD 1.2000E+00
indicating that the clock threshold for the setup and hold trigger is 1.2 V.
TRIGger:A:SETHold:DATa? (Query Only)
Returns the voltage threshold and data source for the setup and hold trigger.
Group Trigger
Syntax TRIGger:A:SETHold:DATa?
Related Commands TRIGger:A:SETHold:CLOCk?
Examples TRIGGER:A:SETHOLD:DATA? might return
:TRIGGER:A:SETHOLD:DATA:SOURCE CH2;THRESHOLD 80.0000E-3
TRIGger:A:SETHold:DATa:SOUrce
Sets or returns the data source for the setup and hold trigger. Youcannot specify
the same source for both clock and data.
For DPO models, you can specify only a single data source. Data sources for DPO
models may be one of CH1-CH4 or the Auxin port (EXT or AUX).
For MSO models, you can specify any combination of CH1-CH4 and D0-D15 as
the data sources.
Group Trigger
2-448 MSO4000 and DPO4000 Series Programmer Manual