Commands Listed in Alphabetical Order
TRIGger:A:BUS:B<x>:SPI:DATa{:OUT|:MOSI}:VALue
Sets or returns the binary data string to be used for a SPI trigger if the trigger
condition is MOSI or MISOMOSI. Applies to bus <x>, where x is the bus number.
Conditions This command requires a DPO4EMBD application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:SPI:DATa{:OUT|:MOSI}:VALue <QString>
TRIGger:A:BUS:B<x>:SPI:DATa{:OUT|:MOSI}:VALue?
Arguments <QString> is the binary data string with the number of bits specied by the
TRIGger:A:BUS:B<x>:SPI:DATa:SIZecommand. The only allowed characters
in the QString are0,1,andX.
TRIGger:A:BUS:B<x>:SPI:DATa:SIZe
Sets or returns the length of the data string to be used for a SPI trigger if the
trigger condition is MISO, MOSI, or MISOMOSI. Applies to bus <x>, where x
is the bus number.
Conditions This command requires a DPO4EMBD application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:SPI:DATa:SIZe <NR1>
TRIGger:A:BUS:B<x>:SPI:DATa:SIZe?
Arguments <NR1> is the length of the data string in bytes.
TRIGger:A:BUS:SOUrce
Sets or returns the source for a Serial bus trigger.
Conditions This command requires a DPO4AUTO or DPO4EMBD application module.
Group Trigger
2-424 MSO4000 and DPO4000 Series Programmer Manual