Commands Listed in Alphabetical Order
TRIGger:A:BUS:B<1-4>:AUDio:DATa:WORD
Sets or returns the trigger data alignment for the AUDIO bus.
Conditions This command requires DPO4AUDIO application module.
Group Trigger
Syntax TRIGger:A:BUS:B<1-4>:AUDio:DATa:WORD {EITher|LEFt|RIGht}
TRIGger:A:BUS:B<1-4>:AUDio:DATa:WORD?
Arguments EITher aligns the trigger data to either left or right.
LEFt aligns the trigger data to the left.
RIGht aligns the trigger data to the right.
TRIGger:A:BUS:B<x>:CAN:CONDition
Sets or returns the CAN trigger condition for bus <x>, where x is the bus number.
Conditions Requires a DPO4AUTO application module.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:CAN:CONDition
{SOF|FRAMEtype|IDentifier|DATA|IDANDDATA|EOF|ACKMISS}
TRIGger:A:BUS:B<x>:CAN:CONDition?
Arguments SOF enables triggering on the start of frame.
FRAMEtype enables triggering on the type of frame.
IDentifier enables triggering on a matching identier.
DATA enables triggering on matching data.
IDANDDATA enables triggering on a matching identier and matching data.
EOF enables triggering on the end of frame.
ACKMISS enables triggering on a missing acknowledge.
MSO4000 and DPO4000 Series Programmer Manual 2-397