Commands Listed in Alphabetical Order
Syntax TRIGger:A:BUS:B<x>:FLEXray:CONDition
{SOF|FRAMEType|IDentifier|CYCLEcount|HEADer|DATA|IDANDDATA|EOF|ERROR}
TRIGger:A:BUS:B<x>:FLEXray:CONDition?
Arguments SOF sets the FLEXRAY trigger condition to start of frame.
FRAMEType sets the FLEXRAYtrigger condition to frame type.
IDentifier sets the FLEXRAY trigger condition to identier.
CYCLEcount sets the FLEXRAY trigger condition to cycle count.
HEADer sets the FLEXRAY trigger condition to header.
DATA sets the FLEXRAY trigger condition to data.
IDANDDATA sets the FLEXRAYtrigger condition to id and data.
EOF sets the FLEXRAYtrigger condition to end of frame.
ERROR sets the FLEXRAY trigger condition to error.
Examples TRIGGER:A:BUS:B1:FLEXRAY:CONDITION? might return
TRIGGER:A:BUS:B1:FLEXRAY:CONDITION SOF indicating the
GLEXRAY condition is start of frame.
TRIGGER:A:BUS:B1:FLEXRAY:CONDITION? might return
TRIGGER:A:BUS:B1:FLEXRAY:CONDITION SOF indicating the
GLEXRAY condition is start of frame.
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue
Sets or returns the binary data string to be used for FLEXRAY cycle count high
value.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue <QString>
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:HIVALue?

Arguments <QString> isaquotedstringthatisthecyclecounthighvalue.

Examples TRIGGER:A:BUS:B1:FLEXRAY:CYCLECOUNT:HIVALUE “110010” sets the
cycle count high value to 110010.
2-402 MSO4000 and DPO4000 Series Programmer Manual