Commands Listed in Alphabetical Order
Syntax TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue <QString>
TRIGger:A:BUS:B<x>:FLEXray:CYCLEcount:VALue?
Arguments <QString> is a quoted string that is the FLEXRAYbinary data string that is the
cycle count low value.
Examples TRIGGER:A:BUS:B1:FLEXRAY:CYCLECOUNT:VALUE “11001101” sets the
cycle count value to 11001101.
TRIGGER:A:BUS:B1:FLEXRAY:CYCLECOUNT:VALUE? might return
TRIGGER:A:BUS:B1:FLEXRAY:CYCLECOUNT:VALUE "XXXXXX" indicating the
cycle count value is don’t care.
TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALueSets or returns the high binary data string to be used for FLEXRAY trigger if
trigger condition is ID or IDANDDATA.
Group Trigger
Syntax TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue <QString>
TRIGger:A:BUS:B<x>:FLEXray:DATa:HIVALue?
Arguments <QString> is a quoted string that is the FLEXRAY binary data high value.
Examples TRIGGER:A:BUS:B1:FLEXRAY:DATA:HIVALUE
"11001101XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXX1" sets the binary data string high value to
"11001101XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXX1".
TRIGGER:A:BUS:B1:FLEXRAY:DATA:HIVALUE? might
return TRIGGER:A:BUS:B1:FLEXRAY:DATA:HIVALUE
"XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXX" indicating the binary data string high value is don’t care.
TRIGger:A:BUS:B<x>:FLEXray:DATa:OFFSetSets or returns the offset of the data string in bytes to be used for FLEXRAY
trigger.
2-404 MSO4000 and DPO4000 Series Programmer Manual