Commands Listed in Alphabetical Order
INrange sets the FLEXRAY data qualier to in range.
OUTrange sets the FLEXRAY data qualier to out of range.
Examples SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:QUALIFIER
LESSTHAN sets the data qualier to LESSTHAN.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:QUALIFIER? might
return SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:QUALIFIER
EQUAL indicating the data qualier is EQUAL.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe
Sets or returns the length of the data string in bytes to be used for FLEXRAY
trigger.
Group Search
Syntax SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
Arguments <NR1> is the length of the data string in bytes. Length range is 1 to 8.
Examples SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:SIZE 8 sets the
data size to 8 bytes.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:SIZE? might return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:SIZE 1 indicating
thedatasizeis1byte.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue
Sets or returns the low binary data string used for FLEXRAYtrigger condition if
trigger condition is ID or IDANDDATA.
Group Search
Syntax SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
MSO4000 and DPO4000 Series Programmer Manual 2-343