Converse Command Debugging

Table D-3. Converse Command Debugging

 

 

SYMPTOM

 

CAUSES

 

EVIDENCE

 

 

 

 

VRU timed out awaiting first

 

 

 

 

digit.

 

 

 

 

VRU error log/trace.

 

 

 

 

VRU first digit timeout too

 

Check VRU script. Check

 

 

short.

 

converse second data

 

 

 

 

delay.

 

 

Inter-digit timeout too short on

 

Check VRU script.

 

 

first prompt and collect.

 

 

 

 

Faulty hardware.

 

Diagnostics.

Digits incomplete.

 

Converse data delay too short.

 

Check administration.

 

 

Faulty hardware.

 

Diagnostics.

Second set of digits is

 

VRUs first prompt timed out.

 

Check administration.

the same as the first

 

 

 

 

digits passed.

 

 

 

 

 

 

Faulty hardware.

 

Diagnostics.

DATA RETURN:

 

 

 

 

No digits returned to the

 

Flash not recognized by

 

VRU error log/trace.

DEFINITY switch.

 

switch.

 

 

 

 

 

 

Check flash timing on VRU.

 

 

Converse data return FAC not

 

Check administration.

 

 

administered.

 

 

 

 

VRU does not return FAC.

 

VRU script. Transfer

 

 

 

 

attempt vector event.

 

 

VRU returns incorrect FAC.

 

VRU script. Transfer

 

 

 

 

attempt vector event.

 

 

Digit timeout during FAC.

 

Transfer attempt event.

 

 

Converse data return FAC

 

Check dialplan.

 

 

overlaps with other entries in

 

 

 

 

the dialplan

 

 

 

 

Faulty hardware.

 

Diagnostics.

Not all digits returned to

 

Digit timeout after FAC.

 

None unless VRU logs being

the DEFINITY switch.

 

 

 

dropped by DEFINITY.

 

 

Overflow of Call Prompting

 

Vector Event.

 

 

buffer

 

 

 

 

Faulty hardware.

 

Diagnostics.

Collect announcement

 

Too many digits returned by

 

Check VRU script.

not heard.

 

VRU.

 

 

 

 

Faulty hardware.

 

Diagnostics.

 

 

 

 

 

Issue 4 September 1995 D-11