Issue 4 September 1995 N-1
N

Call Vectoring System Parameters

G3iV1.1 and G3V2 System Parameters

1. The total of VDN, Station, an d Login ID extensions cannot exceed 25,000.
2,000 for G3rV3
7,084 for G3rV3 for "Simultaneous 3-way Conf. Calls"
Table N-1. Maximum System Parameters for Call Vectoring/EAS
for G3V2
ITEM G3iV1.1-
286 G3vsV2
ABP/PBP G3sV2
ABP/PBP G3iV2-
386 G3rV2
Call Vectoring
Multiple Splits per Call 3 NA/3 NA/3 3 3
Priority Levels 4 NA/4 NA/4 4 4
Recorded An nouncement 128 NA/128 NA/128 128 256
Steps per Ve c tor 32 NA/32 NA/32 32 32
Vector Dire ctory Numbers1500 NA/100 NA/100 512 20,000
Measured VDNs 500 NA/100 NA/100 512 2,000
Vectors per System 2 56 NA/48 NA/48 256 512
Expert Agent Selection (EAS)
Skill Groups NA NA/24 NA/24 99 255
VDN Skill Preferences NA NA/3 NA/3 3 3
Multiple Skill s p er Call NA NA/3 NA/3 3 3
Multiple Skill s p er Agen t 4 NA/4 NA/4 4 4
Agent Login ID s NA NA/450 NA/450 1,500 10,000