Barco 26-0702000-00 manual fåéìí=páòáåÖ=~åÇ=pÅ~äáåÖ=m~åÉä, Menu Orientation

Models: 26-0702000-00

1 474
Download 474 pages 62.9 Kb
Page 219
Image 219
fåéìí=páòáåÖ=~åÇ=pÅ~äáåÖ=m~åÉä

Motion

Thres-

hold

Sizing

and

Scaling

Size

and

Position

Reset

5. Menu Orientation

System Menu

~Select Field to Frame to use field-to-frame de-interlacing. This mode avoids motion artifacts by converting individual input fields to progressive output frames.

Note

This function is available for interlaced formats only. The

 

button does not appear for progressive scan inputs.

 

 

If Motion Adaptive de-interlacing is selected, press {Motion Threshold} to adjust the threshold of the motion adaptive de-interlacer. Because adjustment is rarely required, it is recommended that you leave the function at its default setting.

Range: 0 to 15

Default: 15

fåéìí=páòáåÖ=~åÇ=pÅ~äáåÖ=m~åÉä

On the Input Setup Menu for universal inputs, press {Sizing and Scaling} to display the Input Sizing and Scaling section. This panel enables you to scale a non-native resolution input up (or down) to the system’s native resolution, set the image’s sizing and scaling, pan and zoom the image, and set a mask if required.

The panel has one section, as shown below, plus additional sections that appear, depending on your selection.

Sizing and Scaling

 

 

 

 

 

 

 

 

 

 

 

 

Size

 

Pan

 

Mask

 

 

and

 

Zoom

 

 

 

Position

 

Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5-94.Input Sizing and Scaling section

In the Input Sizing and Scaling section, press {Size and Position} to display four size/position value buttons, plus the convenient Quick Adjust section.

~Press {H Size} or use the knob to change the universal input’s horizontal size. Remember that {H Size} and {V Size} track together if the {Lock} is enabled.

~Press {V Size} or use the knob to change the universal input’s vertical size.

~Press the {Lock} button to lock or unlock H and V tracking. When locked, both parameters track together. When unlocked, H and V can be adjusted independently.

~Press {H Position} or use the knob to change the universal input’s horizontal position along the X axis.

~Press {V Position} or use the knob to change the universal input’s vertical position along the Y axis.

~Press {Reset} to reset all size and position values to default (including those performed from the Quick Adjust Section). Any Mask values present in the image will not be affected.

FSN Series • User’s Guide • Rev 01

 