q~ääó=pÉíìé

6. System Setup

Tally Setup

q~ääó=pÉíìé

 

FSN Series system setup: Step 15

15

This procedure enables you to assign inputs to the system’s 24 tally relays, set tally

markers, and set individual tally closures.

S Prerequisite — Ensure that you are familiar with the following menus and connector specifications:

~ Tally Setup Menu Chapter 5, Tally Setup Menu,” page 235. ~ Tally Connector Appendix A, Tally Connector,” page 443.

„ Set up Tallies — Use the following steps to set up tallies:

1. In the Menu Bar, press {System} to access the System Menu.

2. Press {Tally Setup} to display the Tally Setup Menu.

3. Use the Select Tally control to select the tally you wish to set up (1 through 24).

4. Press {Select Input} to display the Input Selection Keypad. Select the desired input that you wish to tally, and press {Apply}.

5. Press {Select Color} to display the Select Color Pop-up, and choose a red, green or amber color block to identify the tally.

Note

Remember that this function is designed only to assist the engineer who is setting up tallies. It provides a visual menu indication of the type of tally, but the function does not affect tally operation.

6.Use the Select Output control to select the output for which you want to set a relay closure. All outputs are grouped in the table.

7.Press {Set Tally Closure} to set a relay closure for the highlighted output. An “x” in the highlighted cell indicates that a closure is set.

8.Repeat steps 6 and 7 for all outputs that you wish to set tally closures.

9.Ensure that the physical tally output is properly connected to the target device’s tally input, e.g., on the camera’s CCU. In Appendix A, refer to the “Tally Connector” section on page 443 for pinouts.

10.Repeat from step 3 to set additional tallies.

„Clear Tallies — Use the following steps to clear tallies:

1.Use the Select Tally control to select the tally you wish to clear.

2.Press {Clear Input} to remove the input from the table.

3.Use the Select Output control to select the output that you wish to clear.

4.Press {Clear Tally Closure} to clear the “x” from the highlighted output.

5.Repeat from step 11 to clear additional tallies.