Barco 26-0702000-00 manual 8IP Address Reset Switch, 9Serial Ports, Ethernet Port, 11Ref In

Models: 26-0702000-00

1 474
Download 474 pages 62.9 Kb
Page 46
Image 46
8)IP Address Reset Switch

2. FSN-1400 Orientation

Card Descriptions

8)IP Address Reset Switch

Using a small tool such as a paper clip, press the IP Address Reset Switch for 5 (five) seconds. This action resets the chassis IP address to the default value of 192.168.0.4, and then performs a factory reset. Please note:

~This is the same as pressing {Factory Reset} on the Reset Menu. In Chapter 5, refer to the “Reset Menu” section on page 274 for details.

~Use the Com Setup Menu to change the IP address if required. In Chapter 6, refer to the “Communications Setup” section on page 285 for details.

Following are descriptions of all components on the System card’s rear panel:

9)Serial Ports

Two DB-9 connectors are provided for Serial connections. In Appendix A, refer to the “Serial Connectors” section on page 442 for details.

Note

10) Ethernet Port

This function is currently not implemented.

One RJ-45 connector is provided for a 10/100 Ethernet connection between the FSN Series control panel and the FSN-1400. For multiple Ethernet connections, an Ethernet switch is recommended. There are two LEDs on the connector:

Link Speed 9)Serial Ports10) Ethernet Port

Link/Activity 11)Ref InManual backgroundManual background

Figure 2-5.Ethernet Connector

~When a valid link is present, the amber Link Speed LED indicates 100mb Ethernet speed when lit, and 10mb speed when off.

~The green Link/Activity LED indicates that a link is present when lit, and link activity when blinking.

Please note:

~In Appendix A, refer to the “Ethernet Connector” section on page 441 for Ethernet connector pinout details.

~Use the Com Setup Menu to change the chassis’ IP address. In Chapter 6, refer to the “Communications Setup” section on page 285 for details.

~Refer to the “FSN Series Ethernet Connections” section on page 48 for more information about Ethernet.

11)Ref In

One BNC is provided for an analog Reference Input connection. Accepted video reference signals are black burst, SMPTE bi-level sync and tri-level sync.

Note

In Appendix A, refer to the “Reference Video Input Specifications” section on page 433 for detailed information about the allowed frame rates for the reference input.

46

 

FSN Series • User’s Guide • Rev 01

 

Page 46
Image 46