Barco 26-0702000-00 manual q~ääó=q~ÄäÉ, Menu Orientation, FSN Series • User’s Guide • Rev

Models: 26-0702000-00

1 474
Download 474 pages 62.9 Kb
Page 236
Image 236
q~ääó=q~ÄäÉ

5. Menu Orientation

System Menu

q~ääó=q~ÄäÉ

The figure below illustrates a sample Tally Table.

 

 

 

 

 

 

 

 

 

 

 

 

Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tally

Input

 

PGM

 

PST

 

 

 

 

 

Installed Aux Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

M1

M2

P

M1

M2

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1

 

CAM1

x

x

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

CAM1

 

 

 

x

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

CAM2

x

x

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

CAM2

 

 

 

x

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

CAM3

x

x

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

CAM3

 

 

 

x

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5-108.Tally table (sample)

The Tally Table enables you to associate inputs with tally relays, and set tally closures on an output-by-output basis. One row is provided for each of the 24 available tallies.

The yellow highlight indicates the tally that you want to set up. You can touch any row to move the highlight, or use the top Select Tally knob to scroll vertically.

The blue highlight indicates the output for which you want to set (or clear) a relay closure. You can touch any cell to move the highlight, or use the Select Output knob to scroll horizontally. Once an output is selected, press {Set Tally Closure} or {Clear Tally Closure} as required.

The following columns of information are provided:

Tally — two columns are provided for tally:

~The left-hand column indicates the selected relay (1 through 24).

~The right-hand column simply indicates the type of tally you wish to set: red, green or amber. Use the {Select Color} button to select the color.

Input — indicates the input that you wish to associate with the highlighted tally. Use the {Select Input} button to select the desired input, or the {Clear Input} button to remove the input from the table.

PGM — columns are provided for all Program outputs on the M/E Card. If a column heading is grayed out, that output is not available.

PST — columns are provided for all Preview outputs on the M/E Card. If a column heading is grayed out, that output is not available.

Note

For both the PGM and PST columns, P = Program Bank, M1 = the M/E 1 bank, and M2 = the M/E 2 bank.

Installed Aux Outputs — columns are provided for all installed Auxiliary outputs on the M/E Card, and on the optional UOC and NAC cards. Closures can be set for all Aux outputs, even if the associated card(s) is not installed.

236

 

FSN Series • User’s Guide • Rev 01

 

Page 236
Image 236
Barco 26-0702000-00 manual q~ääó=q~ÄäÉ, Menu Orientation, FSN Series • User’s Guide • Rev