lìíéìí=páòáåÖ=~åÇ=pÅ~äáåÖ=m~åÉä

Sizing

and

Scaling

Size

and

Position

Reset

5. Menu Orientation

System Menu

lìíéìí=páòáåÖ=~åÇ=pÅ~äáåÖ=m~åÉä

From the UOC Setup Menu, press {Sizing and Scaling} to display the Output Sizing and Scaling Panel. This panel enables you to size and scale the universal output to a different size, position, resolution and mask, as required.

The panel has one Output Sizing and Scaling section, (as shown below) plus additional sections that appear, depending on your selection.

Sizing and Scaling

 

 

 

 

 

 

 

 

 

 

 

 

Size

 

Pan

 

 

 

 

and

 

Zoom

 

Mask

 

 

Position

 

Source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5-119.Output Sizing and Scaling section

Press {Size and Position} to display four “manual” size/position value buttons, plus the convenient Quick Adjust section.

~Press {H Size} or use the knob to change the universal output’s horizontal size. Remember that {H Size} and {V Size} track if the {Lock} is enabled.

~Press {V Size} or use the knob to change the output’s vertical size.

~Press the {Lock} button to lock or unlock H and V tracking. When locked, both parameters track together. When unlocked, H and V can be adjusted independently.

~Press {H Position} or use the knob to change the output’s horizontal position along the X axis.

~Press {V Position} or use the knob to change the universal output’s vertical position along the Y axis.

~Press {Reset} to reset all size and position values to default (including those performed from the Quick Adjust Section). Any Mask values present in the image will not be affected.

The figure below illustrates the Quick Adjust section, which appears when {Size and Position} is pressed:

Quick Adjust

Fill

 

Fill

 

Fill

H

 

V

 

H/V

 

 

 

 

 

Figure 5-120.Quick Adjust Section

The following adjustments are provided:

~Press {Fill H} to scale the output up (or down) to the selected horizontal resolution. Please note:

Aspect ratio is maintained. Manual size/position adjustments using the four value buttons are maintained.

If the left and/or right edges of the image are manually masked, those edges are used for the Fill H calculations.

FSN Series • User’s Guide • Rev 01

 

249

 