Issue 3 EliteMail VMS/EliteMail Limited
1 - 10 Programming
SECTION 8
FMS LED INDICATIONS The front edge of the FMS ETU has 8 LEDs. LEDs CH1 ~ CH4 indicate
port status as follows:
Off Port idle or not used
On Port busy
The Live LED is red if the KTU is receiving power.
When the MB LED is on, the ETU can be removed.
The DOS (BIOS) LED is red if a BIOS erro r has o ccurred.
The bicolor (BCLR) LED indicates the ap plication status.
Red DOS started (VM application not ready)
Green VM application is running
Orange Error
If BCLR LED is orange, check error type on console screen. After
error is corrected, this LED automatically changes to green.
Do not connect the link between the conso le and the KTU until BCLR turns
green during booting
The hard disk (HD) LED flashes red when Flash Disk is active.
Do not reset the KTU while the HD LED is flashing.
SECTION 9
FMS SWITCHES The main power ON/OFF switch for the FMS( )-U10 ETU can be used to
reset the KTU.
Switch SW1 4-position DIP switch:
1 Normally off (on to enable COM1).
2 Normally off. When 1 and 2 are both on, COM1 is enabled for
HOSTKEY and the VM application stops working (Maintenance).
3 On – COM2 (Remote/RJ11)
Off – COM1 Local connection
4 Normally off (On to boot up to DOS prompt).
If switch SW1, position 1, 2, 3, or 4 is changed, the ETU must be
rebooted (MB switch off, then on).