Figure 12-65 PW-HE Interface
The PW-HE interface is treated like any existing L3 interfa ce and operates on on e of the follo wing nodes:
Bridged interworking (VC type 5 or 4) node—PW will carry cust om er E th erne t fr am es w it h I P
payload. The S-PE device must perform ARP resolution for customer IP add resses l ear nt over
PW-HE, which acts as a broadcast interface.
IP interworking node (VC type 11)—The PW-HE acts as a point-to-point interface. Hence, there will
be two types of PW-HE interface-PW-Ether and PW-IW. These PW’s can terminate into a VRF or
the IP global table on SP-E.
Viewing the PW-HE configuration
To view the PW-HE configuration:
Step 1 Right-click the required device in Prime Network Vision and choose Inventory.
Step 2 In the logical inventory window, choose Logical Inventory > PW-HE. The list of PW-HE interfaces
configured in Prime Network are displayed in the content pane.
Step 3 From the PW-HE node, choose a PW-HE interface. The PW-HE interface details are displayed in the
content pane as shown in Figure 12-66.
Layer3 Peering
320493
CE L2
A-PE S-PE
P1
MPLS Access
Network
Global IP/MPLS
Cor Network