20-56
Cisco Prime Network 4.0 User Guide
OL-29343-01
Chapter 20 Monitoring MToP Services
Configuring Clock
Command Navigation Description
Create PTP
Clock Global (For ASR 901/903)
Right-click Clock node >
Commands > Configuration >
(For ASR 9000)
Right-click Clock node >
Commands > Configuration >
PTP >
Identify the clock in the network with the
highest priority. The clock with the highest
priority is referred to as the master clock. All
the other devices on the network synchronize
their clocks with the master and are referred to
as members. Constantly exchanged timing
messages between master and members ensure
continued synchronization.
The PTP clock port commands are used to
modify PTP on individual interfaces.
Modify PTP
Clock Global (For ASR 901/903)
Expand Clock node > right-click
PTP Service> Commands >
Configuration >
(For ASR 9000)
Right-click Clock node >
Commands > Configuration >
PTP >
Delete PTP
Clock Global Expand Clock node > right-click
PTP Service> Commands >
Configuration >
Create PTP
Clock Port Expand Clock node > right-click
PTP Service> Commands >
Configuration >
Show PTP
Clock Global Expand Clock node > right-click
PTP Service> Commands >
Show >
Modify PTP
Clock Port
Delete PTP
Clock Port
Expand Clock node > select PTP
node > right-click on the selected
PTP interface > Commands >
Configuration >
Create PTP
Interface
Modify PTP
Interface
Physical
inventory > Chassis > Slot > Sel
ect an interface > Commands >
Configuration > PTP