14-18
Cisco Prime Network 4.0 User Guide
OL-29343-01
Chapter 14 Monitoring DWDM Properties
Configuring and Viewing DWDM
PM Optics Data Configure > PM interval: 15-min or 24-hour
Optics alarm type:
lbc—Laser bias current
opr—Optical power on the unidirectional
port
opt—Transmit optical power in dBm
Maximum TCA option: Enable or disable
Maximum threshold option: Choosing Set
configures the value on the device; Reset is the
default. If you select blank, the threshold value
is not used.
Maximum threshold
Minimum TCA option: enable or disable
Minimum threshold option: Choosing Set
configures the value on the device; Reset is the
default. If you select blank, the threshold value
is not used.
Minimum threshold
PM OTN Data PM interval: 15-min or 24-hour
OTN alarm type. For a list of types and their
descriptions, see the OTN PN Settings Tab
information in Table 14-6 on page 14-12.
TCA option: Enable or disable
Threshold option: Choosing Set configures the
value on the device; Reset is the default. If you
select blank, the threshold value is not used.
Threshold value
Transm it Pow er Transmit power in dBm
Option: Set or reset transponder Tx threshold
Rx LOS Threshold Rx LOS threshold value
Option: Set or reset transponder Rx threshold
Command Navigation Input Required and Notes