INSTRUCTION DESCRIPTIONS

CLR

Clear Accumulator

Instruction Format:

CLR D

Opcode:

CLR

 

23

 

8

7

4

3

0

 

 

 

 

 

 

 

 

 

 

 

 

DATA BUS MOVE FIELD

 

0 0 0

1

d 0

1 1

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL EFFECTIVE ADDRESS EXTENSION

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Fields:

D d

A0

B1

Timing: 2+mv oscillator clock cycles

Memory: 1+mv program words

MOTOROLA

INSTRUCTION SET DETAILS

A - 71

Page 340