INSTRUCTION DESCRIPTIONS
MOTOROLA INSTRUCTION SET DETAILS A - 195
Condition Codes:
S — Computed according to the definition in A.5 CONDITION CODE COMPUTATION
L — Set if data limiting has occurred during parallel move.
Class I Instruction Format:
( . . . . . ) S1,D1 Y:ea,D2
( . . . . . ) S1,D1 S2,Y:ea
( . . . . . ) S1,D1 #xxxxxx,D2
Opcode:
MR CCR
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
LF DM T ** S1 S0 I1 I0 S L E U N Z V C
R:Y Register and Y Memory Data Move R:Y
23 16 15 8 7 0
OPTIONAL EFFECTIVE ADDRESS EXTENSION
0 0 0 1 d e f f W 1 M M M R R R INSTRUCTION OPCODE